XT Manual Motor Protectors and Starters
Motor starting and protection in an ideal space-saving and cost-saving solution for panelbuilders and OEMs.

XTPB Pushbutton Actuated (MMP)
The new XTPB MMPs up to 25A are ideally suited for small machines and applications operated by push-button or palm switches.
 

MMP product photo

 

More Info
Manual Motor Protectors and Starters Product Summary
Manual Motor Protectors and Starters Product Literature
XT IEC power Control Presentation

 

Special MMP enclosures with IP40, IP55 or IP65 degrees of protection are available surface mount or installed and feature protection against direct contact, solid foreign bodies and dust, as well as the ingress of water. Whether equipped with protective membranes, locking devices or an emergency stop button, the XTPB will meet your application requirements.

XTPR Rotary Actuated MMP
XTPR MMPs offer a solution for applications from 0.1 to 63A in two small frame sizes. The 63A XTPR has a width of just 55mm, the smallest MMP in the industry! Enclosures with black or red/yellow covers are available for North American and IEC applications in IP41, IP55 or IP65 degrees of protection. XTPR enclosures are available for MMPs with front mount auxiliary contact modules including those with the early-make contact. Padlock attachments and a rotary handle mechanism kit make it easy to mount the XTPR in any enclosure.

A302 Manual Starter and Protector
The A302 Manual Starter and Protector is a 3-phase manual motor starter and protector with an adjustable bimetallic overload and instantaneous magnetic short circuit trip mechanism. A302 starters are UL listed and CSA certified for group installations of motors and single motor installations up to 25 FLA. These manual starters can be field wired for single-phase motor applications by connecting the 3 poles in series.

Features
Compact 45 mm design — saves panel space
Meets UL, CSA and international standards
CE Mark
Class 10 bimetallic thermal overload trip
Single-phase fault sensitivity
Snap-on DIN rail mount capability or can be panel mounted with screws
Open starters can be padlocked in OFF (STOP) position
Terminals are “fingerproof,” located in the vertical plane, easily accessible from the front with screwdriver guide holes provided for ease of wiring
Wide range of accessories, including auxiliary contacts, undervoltage release module and shunt trip can be added to the starter without tools
Group Motor Applications
A302 Manual Starters are UL Listed for Group Motor Installations. A Group Motor Installation can be defined as more than one motor circuit protected by a single set of fuses or circuit breaker. This eliminates the need for individual fusing or circuit breakers for each motor circuit on a branch circuit.
 

The A307, A308 and A309 Manual Motor Protectors
The A307, A308 and A309 family of Manual Motor Controllers feature a rotary ON/OFF manual disconnect, Class 10 adjustable bimetallic overload relay and fixed magnetic short circuit trip capability in one compact unit. Three frame sizes are available: A307 (45 mm) for motors with FLA ratings up to 25A, A308 (55 mm)covers motor FLA ratings up to 50A and the A309 (70 mm) is suitable for motor FLA ratings to 100A.

Features
ON/OFF Rotary Handle with Lockout Provision
Visible Trip Indication
Class 10 Overload Protection
Optional Class 20 Overload Protection for A308 and A309 only
Phase Loss Sensitivity
Ambient Temperature Compensation to 140°F
Fixed Short Circuit Trip — 13 times maximum setting of overload FLA dial
Type 2 Coordination per IEC 947
Identification Markers Standard on Starter Faceplate
DIN Rail or Panel Mount
Accessories include:
  • Front and Side Auxiliary Contacts
  • Trip Indicating Contacts
  • Tamperproof Cover for OLR Dial
  • Undervoltage Release
  • Shunt Trip
  • Thru-the-Door Operators
  • Enclosures
  • 3-Phase Line Side Connecting Links
Group Motor Installations
The A307, A308 and A309 Manual Motor Starters and Protectors are UL Listed for Group Motor Installations and have a short circuit current rating of 50 kA at 480V and 10 kA at 600V.
 

Cutler-Hammer recommends the use of Cutler-Hammer Moulded Case Circuit Breakers wherever possible for Group Motor Installations.
 

 

 

 
 
 
Copyright ©2012 Eaton