Continuous recording mode |
| Range |
Measurement |
Accuracy |
Accuracy of sensor combination |
| 100mA |
0 to 100.0mA |
|±1.0%rdg±5dgt |
|±2.0%rdg±10dgt |
| 1000mA |
0 to 1000mA |
|±2.0%rdg±6dgt |
|
Event recording mode / The maximum value recording mode |
| Range |
Measurement |
Accuracy |
Accuracy of sensor combination |
| 100mA |
0 to 100.0mA |
|±1.5%rdg±7dgt |
|±2.5%rdg±12dgt |
| 1000mA |
0 to 1000mA |
|±2.5%rdg±8dgt |
Capture recording mode
*Accuracy of electric current adjudication is different. For
details, refer to the operation manual |
| Range |
Measurement |
Accuracy |
Accuracy of sensor combination |
| 100mA |
0 to 100.0mA |
|±3.0%rdg±2%fs |
|±4.0%rdg±2.5%fs |
| 1000mA |
0 to 1000mA |
|±4.0%rdg±2%fs |
|
General |
| Operation system |
Successive approximation |
| Input |
AC Voltage (AC 100mV/A) |
| Maximum Circuit Voltage |
AC 170mVrms, 250mV Peak
value |
| Number of input channel |
3 channels |
| Measurement method |
True RMS |
| Measurement interval |
1,2,5,10,15,20,30 sec. /
1,2,5,10,15,20,30,60 min. |
| Over Range Indication |
"OL"mark appears when
exceeding measuring range |
| Warning of voltage of battery |
Battery mark display of 4
stages |
| Battery life |
5000 : about 25 days on
the event record mode ( normal temp. )
5001 : about 40 days on the event record mode ( normal temp. ) |
| Insulation resistance |
50MΩ or more |
| Dimensions |
5000 :
111(L)×60(W)×36(D)mm
5001 : 111(L)×60(W)×42(D)mm |
| Weight |
5000 : about 255g(include
batteries)
5001 : about 315g(include batteries) |
| The maximum display |
1049 counts |
| Applicable standards |
IEC 61010-1:2001 CAT.III
300V Pollution degree 2
IEC 61326(EMC Standard) |
| Power Source |
5000 : Alkaline battery
LR6 × 4
5001 : Alkaline battery LR6 × 6 |
| Accessories |
Instruction Manual
Alkaline battery LR6
Software for making graphs (CD)
7148(USB cable)
9118(Soft Case) |
| Optional |
7185(Extension Cable)
8141 / 8142 / 8143 (Leakage current clamp sensor)
9119(Hard Case) 9135(Carrying Bag) |