| Measurement Range |
-40ºC ~ 300ºC |
| Display Resolution |
0.5ºC . 1ºC for below -20ºC and over
100ºC |
| Measuring Accuracy |
When the ambient temperature is 25
±2ºC and the emissivity (ε) is 1,
| 0 ~ 300ºC: |
bigger value of either of ±1% of the
measured value ±1dgt or ±2ºC ±1dgt. |
| 0 ~ -30ºC: |
|±3ºC ±1dgt |
| below -30ºC: |
|±5ºC ±1dgt |
|
| Repeatability |
within 1ºC ±1dgt |
| Response |
1 sec(90% response) |
| Measuring Diameter |
(45mm/500mm(Optical sensitivity: 90%) |
| Collimation |
Before shipment: 0.95. The value can
be altered between 0.8and 1.0 with the slide switch at the lower
part of the battery compartment(by 0.05 steps).
Laser beam(650nm 1mW JIS class2)specifies the center. |
| Water-Proof Property |
IP67 |
| Auto Power Off |
If no key is pressed for 30 seconds,
the power is shut off automatically. |
| Shock Proof Property |
This instrument or its
function/performance will not be damaged even if it is dropped on
the p tile floor from 1 meter high. |
| Operating Temperature |
0 ~ 50ºC |
| Operating Humidity |
90% rH and below(no condensation) |
| Storage Temperature |
-20 ~ 55ºC(no condensation)(Note): In
the case of longterm storage, the batteries should be removed. |
| Battery |
2 AAA alkaline cell batteries |
| Battery Life |
Approximately 10 hours for continuous
use |
| Housing material |
ABS(antibacterial) |
| Dimension |
120 × 60 × 54mm(Maximum value for each
direction) |
| Weight |
Approx. 123g |
| Accessories |
2 AAA Alkaline Cell Batteries
Instruction Manual
Strap |
| Approved Standard |
CE marking:EMI EN61326 Class B, EMS
EN61326 Annex C
Stability:±5ºC under EMC test environment at 25ºC |